Realistic NFPA CFI-I Latest Exam Duration With Interarctive Test Engine & 100% Pass-Rate Latest CFI-I Test Prep
Realistic NFPA CFI-I Latest Exam Duration With Interarctive Test Engine & 100% Pass-Rate Latest CFI-I Test Prep
Blog Article
Tags: CFI-I Latest Exam Duration, Latest CFI-I Test Prep, CFI-I Reliable Exam Labs, CFI-I Braindumps Torrent, CFI-I Valid Exam Fee
We are committed to providing our customers with the most up-to-date and accurate NFPA CFI-I preparation material. That's why we offer free demos and up to 1 year of free NFPA Dumps updates if the NFPA CFI-I Certification Exam content changes after purchasing our product. With these offers, our customers can be assured that they have the latest and most reliable Certified Fire Inspector I (CFI-1) (CFI-I) preparation material.
NFPA CFI-I Exam Syllabus Topics:
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
>> CFI-I Latest Exam Duration <<
Latest NFPA CFI-I Test Prep & CFI-I Reliable Exam Labs
If you are still hesitate to choose our ITPassLeader, you can try to free download part of NFPA CFI-I exam certification exam questions and answers provided in our ITPassLeader. So that you can know the high reliability of our ITPassLeader. Our ITPassLeader will be your best selection and guarantee to pass NFPA CFI-I Exam Certification. Your choose of our ITPassLeader is equal to choose success.
NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q31-Q36):
NEW QUESTION # 31
What is the maximum length of dead-end corridors in new mercantile occupancies protected by a supervised automatic sprinkler system?
- A. 75 ft (23 m)
- B. 50 ft (15 m)
- C. 100 ft (30 m)
- D. 20 ft (6 m)
Answer: A
Explanation:
Dead-end corridors are portions of a hallway that do not lead to an exit, posing challenges for occupant evacuation during a fire. According to NFPA 101, Life Safety Code, Section 36.2.5.2 (New Mercantile Occupancies):
In buildings equipped with a supervised automatic sprinkler system, the maximum allowable length of a dead-end corridor is 75 feet (23 meters).
Without a sprinkler system, the limit is typically much shorter, such as 20 feet (6 meters) or 50 feet (15 meters) depending on occupancy type.
20 ft (A) and 50 ft (B): These limits apply to unsprinklered or higher-risk occupancies.
100 ft (D): This exceeds the allowable limit, even with sprinklers.
Reference:
NFPA 101, Section 36.2.5.2: Dead-end corridor limits for mercantile occupancies
NEW QUESTION # 32
What is the maximum occupant load for a conference room with a total area of 900 ft² (84 m²)?
- A. 120 people
- B. 60 people
- C. 90 people
- D. 30 people
Answer: B
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Occupant Load Calculation:
According to NFPA 101 (Life Safety Code), Table 7.3.1.2, for assembly occupancies without fixed seating (such as conference rooms), the occupant load factor is:
15 ft² (1.4 m²) per person.
Calculation:
Divide the total area of 900 ft² by 15 ft per person: 900ft2/15ft2/person=60people900 , text{ft}